Managing MSSP security for critical hospital infrastructure requires more than vigilance. It requires Context-Aware Logic.
Lenovo ThinkEdge SE455 V3 (AMD EPYC 8004, 64 Cores, NVIDIA L4 GPU).
Status: OPTIMAL for High-Compute Logic.
Objective: Filter benign anomalies (PACS/MRI scans) from genuine threats (Sabotage/Intrusion).
The "Benign Anomaly" Paradox
False positives in hospitals often stem from authorized operations that look like attacks.
Wazuh's default ruleset uses "Atomic Alerting". A medical imaging server connecting to 50 workstations looks like a Network Scan.
We move from Atomic Alerting to Threshold Alerting. We allow aggressive behavior ONLY if the source is known and the intent is verified.
Mathematical logic to eradicate false positives.
We define a specific "Rate Limit". 1 failed login is a typo. 50 failed logins in 1 second is an attack.
The specific timeframe to analyze. Allows for "bursty" traffic from hospital machines without triggering immediate alarms.
Known benign hospital scanners and internal health checks (CDB Lists) are mathematically excluded from alerting.
From Concept to Code.
Create a Constant Database (CDB) list for known safe IPs. Compile using ossec-makelists.
Create a Child Rule overriding the default ID. Set frequency="8" and timeframe="120".
For events matching the Whitelist exactly, set alert level to 0. This effectively "deletes" the noise before it hits the dashboard.
<!-- Step 2: Apply the Formula (Frequency + Time) --> <rule id="100100" level="10" frequency="8" timeframe="120"> <if_matched_sid>5710</if_matched_sid> <same_source_ip /> <!-- The Whitelist Logic --> <list field="srcip" lookup="not_address_match_key">etc/lists/hospital_allowlist</list> <description>High frequency of failed logins (Potentially Brute Force).</description> <group>authentication_failures,</group> </rule> <!-- Step 3: Silence the Noise --> <rule id="100101" level="0"> <if_sid>5710</if_sid> <srcip>192.168.1.50</srcip> <description>Silence false positives from known Hospital Scanner.</description> </rule>
Communicating the "Black Box" value to Hospital Administration.
"Standard security monitoring functions like a basic motion detector. If anything moves, the alarm sounds. In a busy hospital, this creates thousands of false alarms."
Instead of treating every digital 'cough' as a Code Blue, our system applies intelligent criteria:
Analyst Fatigue: CRITICAL. 90% of time wasted on false alarms.